Roots pump - Insufficient vacuum
Changes in process parameters;
The pre-stage pump performance attenuation, overhaul the prepump;
Performance attenuation of pre-stage pump , disassembly maintenance test;
Pipeline blocked, check the inlet filter, clean the pipeline;
Whether the pipelines leak or not, check the whole process pipeline for leakage.
Roots pump - High running current
The bearing is damaged, replace the bearing;
High back pressure, check the pre-stage pump;
Gear wear, replace gear;
Upstream process changes, pressure increases;
The rotor operation is stuck, check the clearance, clean the excess material.
Roots pump - Lubricating oil contamination
The bearing is damaged, replace the bearing;
Exhaust is not smooth, check the exhaust pipeline;
Machine seal or oil seal is damaged, replace and maintain the vacuum pump;
Gear oil not replaced in time, deterioration, replace the gear oil;
The system entrainments too much material, the upstream processing is abnormal, the upstream process needs to be treated.
Roots pump - High temperature
Gear oil filling too much, discharge gear;
Cooling system problems, check the cooling water system;
High exhaust pressure? If the pressure difference between upstream and downstream is too large, check the exhaust port;
Failure of inlet cooling mechanism? The inlet temperature is high, Check the intake air temperature.